No single building has 100% availability, whether it is your office or a hosting site. The best-run sites are built with redundant power, cooling and network, and they still go offline. What matters is whether your staff can keep working if that happens.
Today we are introducing Computle Availability Sets: a second copy of each of your Computle workstations, kept continuously up to date at a second Computle site. If the primary site has an outage, your users move to their replica and carry on working, with their applications, settings and files as they left them.
An availability set is a pair of machines placed so that no single event can take both out at once.
The replica can be a lower specification than the primary to reduce the cost, as long as it can run your users’ work through an outage. We size it with you.


Replicating a full workstation continuously needs a lot of private bandwidth between sites. Our UK sites are joined by our own diverse 100G network, running over separate physical routes, and each customer’s replication runs over a private backbone dedicated to that customer. Over the public internet, a replica falls behind, and a replica that is hours behind is of little use.
Each workstation has a guaranteed 10 Mbps of replication bandwidth, which bursts up to 1 Gbps when there is more to copy, for example after a large project is saved. This keeps the replica seconds behind the primary in normal use and lets it catch up quickly after large changes.
We also control the entire software stack. Our own management system, Computle VMM, orchestrates machines across all of our sites, which is what lets us keep each replica in step and move users between sites in minutes.
Outages are common. The Uptime Institute’s 2025 survey found that half of all data centres had at least one impactful outage in the past three years, and that power problems caused 45% of incidents. The examples below all involved operators with redundant systems and professional staff.
| Date | Operator and location | What happened | Impact |
|---|---|---|---|
| March 2021 | OVHcloud, Strasbourg | A fire destroyed the SBG2 building and damaged neighbouring buildings. | An estimated 3.6 million websites went offline. Customer data and backups held in SBG2 were lost. |
| July 2022 | Google and Oracle, London | Cooling systems failed during the UK’s 40°C heatwave. Google reported multiple redundant cooling systems failing at once. | An outage of around eight hours. |
| October 2022 | SK C&C, Pangyo, South Korea | A fire in a battery room. | Kakao’s services were offline for more than ten hours, including messaging, payments and taxi dispatch for most of the country’s 51 million people. |
| September 2024 | Digital Realty, Singapore | A lithium-ion battery fire in the UPS rooms forced an emergency power shutdown. | Alibaba Cloud and several other platforms were disrupted. Firefighters were still on site a day later. |
| September 2025 | National Information Resources Service, Daejeon, South Korea | A UPS battery fire during maintenance. | 647 government services were disrupted. 858 TB of data, eight years of work for 125,000 civil servants, was permanently lost because it had no backup. |
| March 2026 | AWS, UAE and Bahrain | Drone strikes damaged three facilities. | More than 100 services were disrupted, affecting banks and payment companies. Six months later, some facilities had still not been restored. |
This is not specific to Computle. A practice with 50 workstations in its own office carries the same risk, and usually more of it. An office can flood, catch fire, be broken into, lose power or its internet connection, or be closed by a police cordon or a terrorist incident nearby. Most have no backup power and no second site.
These outages are not always short. In September 2025, a burst water main in Marylebone, central London, put up to two metres of water into basements on Enford Street and York Street and closed Westminster Magistrates’ Court. It took around a year for local businesses to be fully repaired.
Many practices plan to send staff home with laptops and a VPN to a second site. That protects the data, but not the work:
With Computle, the laptop is only the screen and keyboard. The workstation is at a Computle site, so losing the office changes nothing. An Availability Set covers the remaining risk: the site the workstations are in.
Take a 30-person architecture practice with an average charge-out rate of £75 an hour. A lost day is £16,875 in fee-earning time. If a site is lost to a fire, flood or aircraft and it takes three weeks to source and rebuild the machines, that is over £250,000.


You can take a second Computle subscription for every user at another site, but:
With live replication, the replica is a clone of the primary. There is nothing extra to patch or manage, and when a user moves to it, it is their machine as they left it.
It is fully managed by Computle. There is nothing for your IT team or MSP to set up or run. If the primary site goes down, we move your users to their replicas.
We offer 100% availability across the pair: at any time, at least one of a user’s two workstations is available to them.
We work to keep our customers’ costs down. When US tariffs and DRAM prices raised our costs, we absorbed them and froze our prices (our statement on the price freeze). Asking customers to pay more goes against that, and we have not done it lightly. A 100% availability guarantee needs a second machine at a second site, and that machine has a cost.
You pay for the replica machine, with a 40% discount on its compute and storage because it sits idle unless the primary site is down. We do not charge for replication, and there are no licence or switchover fees. At Computle, a replica is a single flat monthly fee covering the hardware and data centre space, on a three-year term:
| Workstation | Standard price per month | As a replica per month |
|---|---|---|
| RTX 5050 | £123 | £73.80 |
| RTX 5070 | £158 | £94.80 |
| RTX 5080 | £209 | £125.40 |
| RTX 5090 | £301 | £180.60 |
Additional hot storage at the second site is £60 per TB per month instead of £100. For the 30-person practice above on RTX 5070 workstations, replicas cost £2,844 a month, about a sixth of the cost of one lost day.
Doing this yourself with third-party replication software means paying for the software, a second workstation, and space and power at a second site.


The second workstation is a £2,300 machine spread over three years. Space and power assumes colocation. A second office costs more.
Availability Sets are available to existing Computle customers now, and are optional. Speak to your account manager and we will set out the cost for your practice.